Configuration
June 2019
13. Configure the Continuous Flow Analysis (optional). This page is only displayed for
14. Configure Alarm Limits for flow analysis, reverse flow and diagnostic chord:
15. Configure the parameters for the local display.
4.2.1
Display items
The Local Display's labels and descriptions are shown below:
Table 4-1: Local display labels, descriptions and valid units
Local display labels, descriptions and valid units
QFLOW — Uncorrected volume flow rate
86
a) Click Next to continue to the Continuous Flow Analysis page, if View
Continuous Flow Analysis setup was selected on the Startup page.
Daniel Gas Ultrasonic meters if both temperature and pressure are set to Live
Analog, Fixed and Base condition correction is selected on the Startup Page.
Configuration parameters include:
a) Enable SOS comparison (requires AGA 8 Detail method).
b) Enable liquid detection and Profile factor limit.
c) Enable Blockage. Enter the percent for Symmetry, Cross-flow, Chords A to D
turbulence.
d) Enable Internal bore buildup.
e) Click Next to continue to the Alarm Limits page.
a) Set low and high flow limits for flow analysis alarms.
b) Enable/Disable Reverse Flow alarm.
c) Set Volume limit and low flow limit for reverse flow alarm.
d) Enable Dual-Configuration meter flow alarm.
Set Error Limit
e) Enable dual-configuation meter speed of sound alarm.
Set Error Limit
f) Click Next to continue to the Local display setup, if View local display setup
was selected on the Startup page.
a) Use the drop-down arrow in the Display Items list box and select or modify
the parameters that will be displayed; the Display items, the Display units
and the Scroll delay.
Installation manual
DAN-20057315
Installation manual