Electrical installation
June 2019
Table 3-2: CPU Module labeling and LED functions
CPU Module
label or LED
WRITE PROT.
DHCP
PORT A
58
Function
•
Write-protect mode - with switch
in the ON position (default
setting) protects configuration
and firmware overwrites.
•
To write configuration changes or
download firmware to the meter
change the switch to the OFF
position
•
Dynamic Host Protocol Server -
enables you to communicate with
a Daniel meter that is not
connected to a network.
•
When the CPU Module switch is in
the ON position, the meter is
enabled to act as a DHCP server
for a single DHCP client connected
to the Ethernet port using a
crossover cable. This should be
used for peer to peer connections
only.
•
When the connection is made,
select to use the Meter Name in
the meter instead of the Meter
Directory Name in order to keep
all log files and configurations
separate from each meter.
•
PORT A override - RS-232 serves as
an override during meter
commissioning to establish
communications and in the event
the user cannot communicate
with the meter due to an
inadvertent communication
configuration change. The
override period is for two minutes.
•
Supports:
—
auto-detected ASCII (Start bit
1, Data Bit 7, Parity Odd/Even,
Stop Bit 1)
—
RTU (Start Bit 1, Data Bit 8,
Parity none, Stop Bit 1)
—
Modbus protocols
•
RS-232 Baud rate=19,200
•
Modbus ID=32
Installation manual
DAN-20057315
Switch position indicator or LED
Switch position
•
ON - (default setting) enables
write protection of the
configuration and firmware
•
OFF - enables writing
configuration changes or
downloading firmware
Switch position
•
ON - the meter is enabled to act as
a DHCP server for a single DHCP
client
•
OFF - disables the DHCP server
Switch position
•
ON - enables RS-232 PORT A
override
•
OFF - (default setting) disables
RS-232 PORT A override
Installation manual