Mechanical installation
June 2019
9. NEVER allow the slings to contact the electronics enclosure. Damage to the
40
Figure 2-10: Correct sling attachment for Shell Shroud meters
enclosure may occur. Use a spreader bar with the slings to prevent contact with the
electronics enclosure and the base enclosure (see
appropriate rated lifting
enclosure then remove the two bolts holding the enclosure to its base and
temporarily remove the head from the meter during the lifting operation. You will
need to unplug the cable from J3 on the Acquisition Module. Two screws hold this
cable in place.
a) Once the lifting operation is complete, reattach and secure the electronics
cable to J3 on the Acquisition Module, return the electronics enclosure to its
original position, replace the bolts, and secure the enclosure in place.
b) Lifting the meter with the upper enclosure installed but without the bolts
installed, may cause the electronics to fall and cause personal injury or
equipment damage.
slings). If the slings do come in contact with the electronic
Installation manual
DAN-20057315