Introduction
June 2019
The 3418 combines the power of two interlocked 4-path British Gas design meters in one
flowmeter body. The second set of chords is the mirror image of the first, which allows the
meter to cancel out the effects of swirl and cross flow. The meter offers bidirectional
measurement and superior low-flow capabilities, without the compromises associated
with conventional technologies.
Figure 1-2: Daniel 3418 Gas Ultrasonic Flow Meter design
A. Transmitter electronics enclosure (explosion-proof) Optional - Local Display with glass
endcap
B. Base electronics enclosure (intrinsically safe)
C. Meter body with transducer assemblies (T-21, T-22 or T-200) (intrinsically safe) covered
by security shrouds
The Daniel Gas Ultrasonic Flow Meter design is available with an optional glass end cap and
a local display.