Emerson Daniel 3410 Series Installation Manual page 75

Gas ultrasonic flow meters
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents

Advertisement

Installation manual
DAN-20057315
Digital input
The Daniel 3410 Series Gas Ultrasonic Flow Meter provides one digital input that can be
used as a general purpose input. The digital input must be configured via the Daniel
MeterLink Tools|Edit/Compare Configuration screen. DI1Mode must be set to Digital
Input/Calibration Input.
DHCP server switch settings
The meter can be configured to act as a DHCP server. The DHCP server is enabled/disabled
via CPU Module DHCP switch as follows:
Table 3-8: DHCP server switch settings
CPU Module switch
Configuration protect switch settings
The meter's configuration parameters and firmware can be protected against changes via
the CPU Module WRITE PROT. switch as follows:
Table 3-9: Configuration protect switch settings
CPU Module switch
External power source connection and fuse
Located inside the Transmitter Electronics Enclosure is a connector for a user-provided
external power source, a 2 Amp fuse and a 24V loop power connection for ultrasonic
meter analog outputs, temperature transmitter or pressure transmitter devices. The
current is limited to 88mA.
Model 3418 GUSM
Electrical installation
DHCP server disabled
DHCP server enabled
OFF
ON
Configuration
Configuration
protected
unprotected
ON (default setting)
OFF
June 2019
75