Electrical installation
June 2019
6. Set or configure the meter operating parameters using Daniel MeterLink. For
54
Figure 3-6: Transmitter electronics field wiring lower terminal block - Type 4
CPU Module
A. Lower Terminal Block
a. FODO Group 1 connections
FODO1
GND1
DI 1 / FODO6
b. AO1
AO1+
AO1-
c. Serial COMs (RS-323, RS-485)
RS-232: RTS, TX, RX, CTS
RS-485: TX+, TX-, RX+, RX- (4-wire Full
Duplex)
RS-485: TX+, TX- (2-wire Half Duplex)
additional installation information refer to the system wiring diagram (see
Installation manual
d. Ethernet
Ethernet (orange and white wire)
Ethernet (orange wire)
Ethernet (green and white wire)
Ethernet (green wire)
B. 24V loop power (for sourcing 4-20mA
inputs/outputs)
C. Power in (10.4VDC - 36VDC)
D. Fuse cover
DAN-20057315
Installation manual