Emerson Daniel 3410 Series Installation Manual page 19

Gas ultrasonic flow meters
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents

Advertisement

Installation manual
DAN-20057315
Table 1-1: Daniel model 3418 meter specifications (part 1)
Daniel 3418 meter specifications
Enclosure materials
Meter performance
Flow specifications
Repeatibility
Velocity range
Table 1-2: Performance specifications
Model 3418
AGA 9 / ISO 17089 Flow rate values (Metric units)
Meter size (DN)
Qmin (m/s)
Qt (m/s)
Qmax (m/s)
Model 3418
AGA 9 / ISO 17089 Flow rate values (US Customary Units)
Meter size (IN)
Qmin (ft/s)
Qt (ft/s)
Qmax (ft/s)
(*) CF = consult factory
Model 3418 GUSM
250 to 600
750
0.5
0.5
3.048
2.591
30.48
25.91
10 to 24
30
1.7
1.7
10
8.5
100
85
(continued)
ASTM B26GrA356.0T6 Aluminum
100% conversion coated and exterior
coated with a polyurethane enamel
ASTM A351 GrCF8MStainless Steel
Passivated
Optional Local Display with a glass endcap on
transmitter enclosure
Model 3418 8-path chordal design
Flow calibrated accuracy is ±0.1% of reading
over entire flow calibration range
OIML Accuracy Class 0.5 with 5 diameters
upstream pipe and no flow conditioner
±0.05% of reading in the specified velocity
range from 5% to 100% (Q
Nominal 0 to 30 m/s (0 to 100 fps) with over-
range performance exceeding 38 m/s (125
fp/s) on some sizes
Meter meets or exceeds AGA 9 2017
Edition / ISO 17089 performance
specifications
900
0.5
2.29
22.86
36
1.7
7.5
75
Introduction
June 2019
)
max
1050
0.5
CF *
CF *
42
1.7
CF *
CF *
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Daniel 3418

Table of Contents