Drive Parameter Registers (Read/Write) (continued)
REGISTER
PARAMETER
(in hex)
300h
E1-01
301h
E1-02
302h
E1-03
303h
E1-04
304h
E1-05
305h
E1-06
306h
E1-07
307h
E1-08
308h
E1-09
309h
E1-10
30Ah
E1-11
30Bh
E1-12
30Ch
E1-13
30Dh
30Eh
E2-01
30Fh
E2-02
310h
E2-03
311h
E2-04
312h
E2-05
Notes (for this page only):
1. Initial value differs depending on the Control Method (A1-02).
2. Initial value differs depending on drive capacity.
7-17
PARAMETER
FUNCTION
Input Voltage Setting
Motor Selection
V/f Pattern Selection
Maximum Ooutput Frequency
Maximum Voltage
Maximum Voltage Frquency
Mid. Output Frequency
Mid. Output Frqeuency Voltage
Min. Output Frequency
Min. Output Frequency Voltage
Mid. Frequency B
Mid. Voltage B
Base Voltage
Reserved
Motor Rated Current
Motor Rated Slip
Motor no-Load Current
Number of Motor Poles
Motor Line-to-Lline Resistance
PARAMETER
LIMITS / DESCRIPTION
SETTING
155 to 255V (230V unit)
310 to 510V (460V unit)
0
General Purpose Motor (TEFC)
1
Blower Cooled Motor (TENV or
0 to Eh
15 preset V/f patterns
Fh
Custom Pattern (using E1-04 to
50.0 to 400.0 Hz
0.0 to 255.0V (230V unit)
0.0 to 510.0V (460V unit)
0.0 to 400.0 Hz
0.0 to 400.0 Hz
155 to 250V (230V unit)
310 to 510V (460V unit)
0.0 to 400.0 Hz
155.0 to 255.0V (230V unit)
310.0 to 510.0V (460V unit)
0.0 to 400.0 Hz
0.0 to 255.0 VAC
0.0 to 255.0 VAC
0.00 to 99.99 or 100.0 to 1500.0 Amps
0.00 to 20.00 Hz
0.00 to 99.99 or 100.0 to 1500.0 Amps
2 to 48 poles
0.000 to 65.000 Ohms
Registers
INITIAL
VALUE
230
460
0
TEBC)
Fh
E1-10)
60.0
230.0
460.0
60.0
(1)
(1)
(1)
(1)
0.0
0.0
0.0
(2)
(2)
(2)
4
(2)