YASKAWA GPD 515/G5 Modbus RTU Technical Manual page 52

Hide thumbs Also See for GPD 515/G5 Modbus RTU:
Table of Contents

Advertisement

Drive Parameter Registers (Read/Write) (continued)
REGISTER
PARAMETER
(in hex)
280h
d1-01
281h
d1-02
282h
d1-03
283h
d1-04
284h
d1-05
285h
d1-06
286h
d1-07
287h
d1-08
288h
d1-09
289h
d2-01
28Ah
d2-02
28Bh
d3-01
28Ch
d3-02
28Dh
d3-03
28Eh
d3-04
28Fh
d4-01
280h
d4-02
291h
d5-01
292h
d5-02
293h
d5-03
294h
d5-04
295h
d5-05
296h
d5-06
Notes (for this page only):
1. Scaling depends on the setting of o1-03.
7-16
PARAMETER
FUNCTION
Frequency Reference 1
Frequency Reference 2
Frequency Reference 3
Frequency Reference 4
Frequency Reference 5
Frequency Reference 6
Frequency Reference 7
Frequency Reference 8
Jog Frequency Reference
Frequency Reference Upper Limit
Frequency Reference Lower Limit
Critical Frequency Rejection 1
Critical Frequency Rejection 2
Critical Frequency Rejection 3
Critical Frequency Rejection Width
Frequency Reference Hold
Function Selection
Speed Limits
Torque Control Selection
Torque Reference Delay Time
Speed Limit Selection
Speed Limit
Speed Limit Bias
Speed/Torque Control Switching
Timer
PARAMETER
LIMITS / DESCRIPTION
SETTING
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.00 to 400.00 Hz (1)
0.0 to 110.0%
0.0 to 100.0 %
0.0 to 400.0 Hz
0.0 to 400.0 Hz
0.0 to 400.0 Hz
0.0 to 20.0 Hz
0
1
0 to 100%
0
Speed Control
1
Torque Control
0 to 1000 msec.
1
Analog Input (term. 13 & 14)
2
–120 to +120%
0 to 120%
0 to 1000 msec.
Registers
INITIAL
VALUE
Disabled
Enabled
d5-04 setting
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
6.00
100.0
0.0
0.0
0.0
0.0
1.0
0
25
0
0
1
0
10
0

Hide quick links: