YASKAWA GPD 515/G5 Modbus RTU Technical Manual page 46

Hide thumbs Also See for GPD 515/G5 Modbus RTU:
Table of Contents

Advertisement

Drive Parameter Registers (U2-XX / Fault Trace and U3-XX / Fault History) (continued)
REGISTER PARAMETER
(in hex)
08Ch
U2-13
08Dh
U2-14
090h
U3-01
091h
U3-02
092h
U3-03
093h
U3-04
094h
U3-05
095h
U3-06
096h
U3-07
097h
U3-08
Notes (for this page only):
1. List of Drive Error Codes can be found in Chapter 8, Error Codes and Troubleshooting.
7-10
PARAMETER
FUNCTION
Drive Status at Fault
Elapsed Time at Fault
Last Fault
Fault Message 2
Fault Message 3
Fault Message 4
Elapsed Time 1
Elapsed Time 2
Elapsed Time 3
Elapsed Time 4
Registers
PARAMETER
BIT
SETTING
NO.
0
1
2
Reverse Running at the time of fault
3
Reset Signal Input at the time of fault
4
5
Drive Operation Ready at the time of fault
6
7
Elapsed Time at the time of fault (in hrs.)
Code of the most recent fault (1)
Code of the second to most recent fault (1)
Code of the third to most recent fault (1)
Code of the fourth to most recent fault (1)
Elapsed Time at the most recent fault occurrence
Elapsed Time at the second to most recent fault occurrence
Elapsed Time at the third to most recent fault occurrence
Elapsed Time at the fourth to most recent fault occurrence
LIMITS / DESCRIPTION
Running at the time of fault
Zero-Speed at the time of fault
Speed Agree at the time of fault
Minor Fault
Major Fault

Hide quick links:

Advertisement

Table of Contents
loading