Monitor Registers (continued)
REGISTER
(in hex)
018h
019h
Minor Fault Content 1
01Ah
Minor Fault Content 2
7-6
FUNCTION
CPF Content 2
BIT
NO.
0
1
2
3
4-15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8-15
Registers
DESCRIPTION
CPF20 Fault
CPF21 Fault
CPF22 Fault
CPF23 Fault
not used
Undervoltage Detection (UV)
Overvoltage Detection (oV)
Heatsink Overtemperature (oH)
Drive Overheat Alarm (oH1)
Overtorque 1 Detection (oL3)
Overtorque 2 Detection (oL4)
2-wire Sequence Input Fault (EF)
During External Baseblock (BB)
External Fault 3 (EF3)
External Fault 4 (EF4)
External Fault 5 (EF5)
External Fault 6 (EF6)
External Fault 7 (EF7)
External Fault 8 (EF8)
Cooling Fan Fault (FAN)
Overspeed (oS)
Speed Deviation (DEV)
PG Open (PGo)
Operator Disconnected (OPR)
Modbus Communication Error (CE)
not used
not used
Motor Overload (oL1)
Drive Overload (oL2)
not used