KEB Combivert F5 Instruction Manual page 59

Lift
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

Parameter description
LA.13
AN2 Offset X
Value range
0,0...±100,0 %
LA.14
AN2 Offset Y
Value range
0,0...±100,0 %
LA.15
AN2 lower limit
LA.16
AN2 upper limit
Valuer range
0,0...±400,0
Limitation of the analog
LA.17
Selection REF-input/AUX-function
To allow further expansions not all values are defined in the bit groups. Undefined values have the same function
as the value 0. The sum of the values is to be entered.
Bit
Input
0...2
3...5
128
6...10
192
256
320
2048
11...15
4096
6144
8192
Setting
Description
0,0 %
The parameter shifts the input characteristic on the X-axis.
Setting
Description
0,0 %
The parameter shifts the input characteristic on the Y-axis.
Setting
Description
LA.15
The parameter serves for the limitation of the analog signal AN2 after the
-400,0
amplifier stage. As no interacting locking exists, it must be observed, that the
lower limit is adjusted smaller than the upper limit. (Exception F5-M: In case
LA.16
of lower limit > upper limit then output value = lower limit).
+400,0
Fig. LA.15/16:
input signal AN2
Setting
0
x
1
2
0
x
8
16
Source1 • (100 %+Source2)
24
32
0
64
x
Setpoint value in percent
0
x
Setpoint value in percent
LA.07/LA.16
-400%
LA.08/LA.15
Function
AN1
AN2
AN3
Source1
Source1+ Souce2
Source1•Source2
Source1 absolute
AN1
AN2
Motor potentiometer
Technology controller
AN3
AN1
AN2
Motor potentiometer
Technology controller
400%
400%
-400%
Description
Selection of the analog input (AN1, AN2,
AN3) as REF analog
Mode of the AUX-function
Selection of Source1 for the AUX-function
Selection of Source2 for the AUX-function