Parameter Description
Ld.11
Maximum torque of inverter
Value range
0,0...xxxx Nm
Ld.12
Maximum torque limitation
Value range
0,0...xxxx Nm
Ld.13
Field weakening speed
Value range
0,0...32000,0
Ld.14 Motor identification (only at Lb.03 = S G or S GL)
Value range
0 - off
1 - start
2 - calcu
3 - ready
Ld.15
DSM max. inductance (only at Lb.03 = S G or S GL)
Value range
0...500 mH
Ld.20
Maximum torque for UPS-operation
Value range
0,0...xxx,0 Nm
Ld.22
Do not change - only for internal use !
Ld.23
Do not change - only for internal use !
Ld.24
Rotation change UPS
Value range
0
1
Setting
Description
Nm
Based on the peak current of the inverter, the maximum torque that can be
supplied by the inverter, is displayed.
Setting
Description
0,95 • Ld.11 Adjustment of the maximum torque limit.
Setting
Description
auto
Input of the field weakening speed according to the data sheet.
rpm
Setting
Description
0
Calibration of the motor resistance and inductance
Adjust „start" with UP key, confirm with Enter
Give drive command and wait approx. two minutes until „ready" is displayed
Cancel the drive command
Setting
Description
auto
The value is automatically set by Ld.14 after calibration..
Setting
Description
xxx,0 Nm Adjustment of the maximum torque limit during UPS-operation. The value be-
comes active, if an input programmed for it is set.
Setting
Description
Serves for the driving change, if it is driven with under-sized UPS automatical-
ly into easy direction.
x
Change the adjusted value, if empty car do not drive upwards.