KEB Combivert F5 Instruction Manual page 40

Lift
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

Parameter Description
LF.33
Jerk at begin of deceleration
Value range
0,10...9,99 m/s³
LF.34
Deceleration
Value range
0,10...2,00 m/s²
LF.35
Jerk at end of deceleration
Value range
0,10...9,99 m/s³
LF.36
Stopping jerk
Value range
0,00...9,99 m/s³
v
LF.30
Driving characteristic with jerk-free acceleration and deceleration
LF.40
Brake release time
Value range
0,00...3,00 s
LF.41
Brake engage time
Value range
0,00...3,00 s
LF.42
Switching threshold at brake deactivation
Value range
0,000...0,010 m/s
GB - 40
Setting
Description
1,00 m/s³
Setting
Description
0,90 m/s²
Setting
Description
0,70 m/s³
Setting
Description
0,40 m/s³ The starting jerk determines the ride comfort on settling on the floor from the
positioning drive. With LF.36="off" the stopping jerk is the same as the jerk at
the end of deceleration (LF.35).
LF.32
LF.31
Setting
Description
0,25 s
Setting
Description
0,25 s
Setting
Description
0,005 m/s
LF.33
LF.34
LF.35
LF.36
t

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents