Parameter description
LA.06
AN1 Offset Y
Value range
0,0...±100,0 %
LA.07
AN1 lower limit
LA.08
AN1 upper limit
Value range
0,0...±400,0
Limitation of the analog
LA.09
AN2 setpoint selection
Input
0
1
2
LA.10 AN2 interference filter
Input
0
1
2
3
4
LA.11
AN2 zero point hysteresis
Value range
0...±10 %
LA.12 AN2 amplification
Value range
0,00...±20,00
GB - 58
Setting
Description
0,0 %
This parameter shifts the input characteristic on the Y-axis.
Setting
Description
LA.07
The parameter serves for the limitation of the analog signal AN1 after the
-400,0
amplifier stage. As no interacting locking exists, it must be observed, that the
lower limit is adjusted smaller than the upper limit. (Exception F5-M: In case
LA.08
of lower limit > upper limit then output value = lower limit).
+400,0
Fig. LA.07/08:
input signal AN1
Setting
Signal
x
0...±10 V
0...±20 mA
4...20 mA
Setting
Average
from
x
none
2 values
4 values
8 values
16 values
Setting
Description
0,2 %
see LA.03
Setting
Description
1,00
see LA.04
LA.07/LA.16
-400%
LA.08/LA.15
Depending on the setting the analog input can process the listed
setpoint signals.
value
A query of the analog signal takes place every millisecond. The
interference filter shall suppress interferences and ripples of the
input signal, by forming the average value from 2, 4, 8 or 16
scanned values for further processing.
400%
400%
-400%
Description
Description