Parameter Description
LF.00
Display of current parameter group „Funct"
LF.01
Max. speed of system
This parameter limits the speed of the system to the adjusted value. For analog setpoint setting applies 0...±10 V
correspond to 0...±LF.01.
Value range
0,000...15,000 m/s
LF.02
Traction sheave diameter
Value range
0...2000 mm
LF.03
Gear reduction ratio/multiplier
Value range
0,00...99,99
LF.04
Gear reduction ratio/divisor
Value range
0,00...99,99
LF.05
Factor rope suspension
Value range
1...8
LF.06
Contract load
Value range
0...65535 kg
LF.10
Control mode
Value range
0
1
2
LF.11
KP Speed controller
Value range
0...32767
Setting
Description
0,000 m/s
Setting
Description
600 mm
Enter the diameter of the employed leading sheave.
Setting
Description
1,00/
Adjustment according to gearbox name plate (possible determination by
30,00
counting the revolutions of the handwheel at one revolution of the leading
sheave).
Example: i = 43:3
LF.3=43
For gearless motors adjust value „1".
Setting
Description
1,00
Adjustment according to gearbox name plate (possible determination by
counting the revolutions of the handwheel at one revolution of the leading
sheave).
Example: i = 43:3
LF.4=3
For gearless motors adjust value „1".
Setting
Description
1
Adjustment according to system data (1:1...8:1)
Setting
Description
0
Adjustment according to system data (possibly number of persons x 75 kg)
Setting
Description
Without speed encoder (open-loop)
Control procedure switchable by digital input
x
With speed encoder (closed-loop)
Setting
Description
auto
Adjustment of the P-amplification of the speed controller. If the KP-values are
too large vibrations occur during the constant drive. If the KP-values are too
small a deviation between setpoint and actual value occurs. It results in tran-
sient effects after the acceleration.