KEB Combivert F5 Instruction Manual page 38

Lift
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

Parameter Description
LF.12
KI Speed controller
Value range
0...32767
LF.13
KI Speed controller Offset
Value range
0...32767
LF.14
KP Current controller
Value range
0...65535
LF.15
KI Current controller
Value range
0...65535
LF.16
Boost
Value range
0,0...25,5 %
LF.17
Autoboost on/off
Value range
0
1
LF.18 Autoboost / amplification
Value range
0,00...2,50
LF.19
Filter time for current loop
Value range
0...5
LF.20
VR Releveling speed
Value range
0,000...0,300 m/s
LF.21
VL Leveling speed
Value range
0,000...0,300 m/s
GB - 38
Setting
Description
auto
Adjustment of the I-amplification of the speed controller reset time.
Setting
Description
auto
Serves for an improved load transfer at high-efficient gearboxes.
Setting
Description
auto
P-amplification of the magnetizing and active current.
Setting
Description
auto
I-amplification of the current controller reset time.
Setting
Description
Depen-
Serves for the adjustment of the U/f-charateristic in open-loop operation. Too
ding on
little torque increase makes the motor soft and the load cannot be lifted. Too
the motor
much torque increase leads to vibration during acceleration and in the posi-
type
tioning drive.
Setting
Description
auto
Autoboost (torque compensation) off
Autoboost is effective in the motor-driven and generatoric operation (recom-
mend for old lift equipmen).
Setting
Description
1,20
Adjustment of the amplification factor for Autoboost.
Setting
Description
3
0 = 0,5 ms
Setting
Description
0,000 m/s With the readjustment speed the lift is driven aligned.
• for a better positioning the drive abort is made without jerk limitation
• it cannot be accelerated from the readjustment speed
• when Lb.05 = 2 or 6, only active if Lb.12 = 0
Setting
Description
0,000 m/s • it cannot be accelerated from the approch speed
1 = 1 ms
2 = 2 ms
3 = 4 ms
4 = 8 ms
5 = 16 ms

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents