KEB Combivert F5 Instruction Manual page 49

Lift
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

Parameter description
LI.00
Display of current parameter group „InFo"
LI.01
Inverter status
This parameter shows the current status (e.g. constant run, acceleration counter-clockwise rotation) of the inverter.
You find a table of all status and error messages in the annex.
LI.03
Set speed
Display
0...±4000 rpm
LI.04
Actual speed
Display
0...±4000 rpm
LI.07
Actual car speed
Display
0...±20 m/s
LI.08
Floor distance
Display
±32767 cm
LI.09
Set torque
Display
0,00...32000,00 Nm
LI.10
Actual torque display
Display
0,00...32000,00 Nm The displayed value corresponds to the current motor torque in Nm. The value is calculated
LI.11
Apparent current
Display
0...1000 A
Description
Display of the current setpoint value. For control reasons the set speed is also displayed,
if the control release or the direction of rotation is not switched. If no direction of rotation
is given, the set speed for clockwise rotation (forward) is displayed.
Description
Display of the current motor speed (encoder channel 1). For control reasons the set speed
is also displayed, if the control release or the direction of rotation is not switched. A counter-
clockwise rotating field (reverse) is represented by a negative sign. Precondition for the
correct display value is the in-phase connection of the motor and the correct adjustment
of the encoder increments as well as the direction of rotation.
Description
Display of the current speed of the lift. For control reasons the actual speed is also
displayed, if the control release or the direction of rotation is not switched. A counter-
clockwise rotating field (reverse) is represented by a negative sign. Precondition for
the correct display value is the in-phase connection of the motor and the correct basic
setting.
Description
Indicates the last travel distance from start to stop.
Description
Description
from the active current. Due to common type variations and temperature drifts of the
motor tolerances of up to 30 % are possible in the base speed range.
Basic requirement for the torque display is the adjustment of the motor data. If the real
motor data deviate strongly from the name plate data, the operating performance can be
optimized by entering the real data. For the start-up the adjustment of the name plate data
is sufficient.
Description
Display of the current motor apparent current.