Parameter Description
Lb.10 In-/ Output configuration
With this parameter the programming of the digital inputs (Lb.11...13) and the digital outputs (Lb.14...17) can be
enabled. The programming is generally inhibited for positioning operation (Lb.01 = 2...4).
Input
1
2
Lb.11
Input function for terminal X2A.15
Input
0
1
2
3
4
5
6
7
8
9
Lb.12
Input function for terminal X2A.17
Input
0
1
2...9
Lb.13
Input function for terminal X2A.13
Input
0
1
2...9
Lb.14
Output function for X2A.24...26 (relay output 1) see table Lb.17
Lb.15
Output function for X2A.27...29 (relay output 2) see table Lb.17
Lb.16
Output function for X2A....18 (relay output 1) see table Lb.17
Lb.17
Output function for X2A.19 (transistor output 2)
Input
0
1
2
3
4
5
6
7
8
9
Setting
Programming
x
inhibited
enabled
Setting
Function
X2A.13
off
X2A.15
Direction of rotation reverse
Contactor control
Quick stopping
Control mode
X2A.17
UPS operation
Safety-gear release
Brake switching surveillance
Contactor control and brake switching surveil-
lance
Correction input
Setting
Function
VR with input-coded setpoint selection
Reset
see Lb.11
Setting
Function
off
V1 with input-coded setpoint selection
see Lb.11
Setting
Function
off
X2A.24
Main contactor activation
X2A.27
Brake handling with phase check
X2A.18
Ready for operation and overspeed
X2A.19
Motor or inverter temperature warning
Activation contol cabinet fan
Speed for deceleration check
Speed for running open doors
Speed deviation warning
Easy direction of rotation UPS
Description
The configuration of the in- and outputs is reset to factory set-
ting.
The programming of the in- and outputs with the parameters
Lb.11...17 is enabled.
Description
Description
Description
Description