5 divided crosshatch
10 divided crosshatch
Cross
16:9 aspect marker (4:3)
15:9 aspect marker (4:3/16:9)
14:9 aspect marker (4:3/16:9)
13:9 aspect marker (4:3/16:9)
4:3 aspect marker
1.85:1 aspect marker
2.35:1 aspect marker
"Each aspect marker" + "Safety marker
in aspect" (4:3/16:9)
The "safety marker in aspect" refers to
the safety marker with respect to the
aspect marker display zone, and can be
preset 1% by 1% in the range of 80-99%.
Corresponding to each aspect marker.
<Marker level>
Set in five steps of 20%, 40%, 60%, 80%
and100%
(3) Shadow function
Creates a shadow outside the aspect areas with 4:3
(16:9 mode), 13:9, 14:9, 15:9, 16:9 (4.3 mode),
1.85:1 (16:9 mode) and 2.35:1 (16:9 mode).
<Types>
"Various aspect markers" + "Shadow"
"Various aspect markers" + "Safety marker in
aspect" + "Shadow"
Shadow only
<Shadow contrast level>
Set in four steps of 0%, 20%, 40% and
60%.
(4) User marker function
Function for the user to draw their desired lines and
boxes in the unit of pixels.
a) No. of types: 100 types: 10 scenes x 10 types
(1 scene: 10 types)
b) No. of colors: 6
c) Drawable sizes: 1920 x 1080 pixels
d) Drawing method: Switch or USB mouse
* Patent pending
(5) UMD/IMD display with TSL protocol
Material display function controlled by RS485
Either TSL or user display should be selected
for the UMD/IMD display (MENU selection).
a) Standard: RS485
b) Connector: R J-45 (loop through)
c) Number of connections: up to 32 devices
(per line)
d) Protocol: TSL UMD V3.1
e) Characters: ASCII (alphanumeric), up to 8
characters, 7 colors
f) TALLY display: Red/Green/Amber
Display in the screen or LED display
(4:3/16:9)
(4:3/16:9)
(4:3/16:9)
(16:9)
(16:9)
(16:9)
- 61 -
g) Display position: Top/bottom
(6) UMD/IMD display with user display
A function used to set an arbitrary material
name on the channel basis (SDI-A, SDI-B,
VBS-A, VBS-B, option module) and display the
material name when switching the inputs.
a) Characters: ASCII (alphanumeric), up to 8
characters, 7 colors
b) Display position: Top/bottom
(7) USB memory function
a) Content of the memory
MENU setting
User marker
PRESET data

7-5 Remote Control

(1) Parallel remote control
Input connector: HD D-SUB 15-pin
CH A/B switching
SDI ON/OFF
COLOR/MONO switching
4:3/16:9 switching
MARKER ON/OFF
SHADOW ON/OFF
R TALLY ON/OFF
G TALLY ON/OFF
CROMA UP ON/OFF
SHADOW0 ON/OFF ( )
SHADOW20 ON/OFF ( )
SHADOW40 ON/OFF ( )
SHADOW60 ON/OFF ( )
USER MARKER SCENE* ON/OFF ( )
* : 1 10
* For the pin function, refer to " " Data 2 Par-
allel Remote Pin Function".
* In addition to default setting, user setting is
possible.
The " " marked settings are used in the
USER mode.
(2) RS485 remote control
(The controller SRC-400 is optional.)
a) Connector: RJ-45 (loop-through)
b) Maximum number of connections: 32 units
Extension by increasing the number of lines