(17) Auto Setup Function for Color Temperature
The color temperature, which was difficult to
adjust before is simply and automatically ad-
justable in each steps without PC, connecting this
ASP-100 (Ver.1 or later) Auto Setup Prove to the
USB port on monitors.
And it is also able to be used as the measuring
instrument for measuring color temperature
(color point of x, y) and contrast.
(18) 2x/4x zoom function
This function enlarges the input signal 2x and
4x without scaling, and allows you to check the
scratch on the CCD of camera and fine details of
the image.
(19) Image & TEST signal MIX function
While the image is displayed, "pluge signal of
-2%/0%/+2%"can be displayed at the same time on
the corner of the screen (small enough not to dis-
turb the image) so that you can check if there is
no "black sun" effect caused by the brightness
adjustment while looking at the image.
The "brightness signal of 100 to 109%" is also
displayed at the same time so that you can check
if the signal of 100% to 109% is not saturated
when it is input during the contrast adjustment.
(20) White balance adjustment assist function
When adjusting white balance, each switch on
the front can be assigned to the direct switch for
the white balance adjustment, which allows you
to adjust the white balance quickly and easily.
When you remote control the white balance
adjustment using a USB mouse, various adjust-
ment
buttons
(BRIGHTNESS,
R/G/B BACKGROUND, R/G/B GAIN) are dis-
played on the screen with GUI. The white balance
can be adjusted with ease as if you have an oper-
ation panel at hand.
(21) UMD/IMD display with TSL protocol
A function is used to integrally control the
UMD/IMD display using "TSL UMD protocol
V3.1".
Material display (alphanumeric) and TALLY
display can be displayed.
Up to 32 devices can be integrally controlled per
one line using RS485.
By increasing the number of lines, you can set
the IDs and perform individual control for up to
96 devices.
(22) UMD/IMD display with user display
Sets a material name (alphanumeric) with up
to 8 characters to individual monitor for each in-
put (SDI-A/SDI-B/VBS) and displays the preset
material name with UMD/IMD display when the
input channel is switched.
CONTRAST,