Technical data – Device
Internal speaker, sound
The DLT-V72 is equipped with an internal speaker as standard (2 W).
The system messages from the industrial PC are output via this speaker.
The internal speaker is configured in the audio settings for the operating system in question.
5.2.

Environmental conditions

5.2.1.

DLT-V72 without integrated UPS

Operating temperature
Storage temperature
Relative humidity
Mechanical vibration
and shock resistance
IP protection class
5.2.2.

DLT-V72 with integrated UPS (optional)

The environmental conditions are described in the following chapter:
15.1 Integrated UPS (optional)
DLT-V72 Operating Instructions V2.50 Preliminary
-30 to +50 °C
Specification according to EN 60068-2-1/2
-30 to +65 °C
Specification according to EN 60068-2-1/2
10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP66 for DLT-V7210 and DLT-V7212
IP65 for DLT-V7210K