Electrical installation, cable connection, cable cover
12.5.
Closing off unused cable openings
Close off all unused cable openings of the rubber seal using the accompanying blind plugs so that
they are sealed.
Fig. 12.8: Unused cable outlets sealed off with blind plugs
12.6.
Attaching the cable cover
NOTICE: Physical damage
Not sealed device due to incorrect attachment of the cables and the cable cover.
The protection class/category of the DLT-V72 is only ensured if the cable cover is properly
installed.
Improper installation can result in liquid penetrating into the DLT-V72 during operation. There is
then a risk of short-circuiting, corrosion and wear.
Place the cable cover in the DLT-V72 housing slot.
Screw the cylinder-head screws loosely into the holes of the cable cover.
Then fully tighten the screws with 3 Nm torque.
Fig. 12.9: Cable cover closed and screwed together
DLT-V72 Operating Instructions V2.50 Preliminary
109 / 140