Summary of Contents for Advantech-DLoG DLT-V6210FL
Page 1
User Manual DLT-V6210FL Industrial Computer...
Page 2
® and RAM Mount™ are both trademarks of National Products Inc., 1205 S. Orr Street, Seattle, WA 98108. DLT-V6210FL devices can be delivered with or without preinstalled software. For devices with preinstalled software observe the associated license agreements. We recognize all national and international trademarks and product names.
Current manual versions The latest versions of our manuals are available on our websites: www.advantech.com Observe safety instructions WARNING Please read and observe the “DLT-V6210FL Safety Instructions” delivered enclosed with the product. 4 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Available DLT-V6210FL manuals 1.1. Design elements in the manual Personal injury Information with regard to personal injury is shown in this manual as follows (signal words for indicating risk level): DANGER / WARNING / CAUTION DANGER means that death or severe bodily injury will occur if this information is not observed.
(e.g. logistics, warehouse, manufacture site). Any other or additional usage beyond this shall be deemed as improper usage. The user / operator of DLT-V6210FL is solely responsible for any resulting damage. This also applies to any unauthorized modifications made to this device.
Advantech Service Centers LCD display The LCD display of DLT-V6210FL series fulfills the highest quality standards and was inspected for pixel defects. However, due to technological reasons pixel defects can occur. This is not a malfunction; it is a part of the technical specifications.
Functional description 2.4. Functional overview DLT-V6210FL front side Fig. 2.1: Functional overview DLT-V6210FL front side DLT-V6210FL back side Fig. 2.2: Functional overview DLT-V6210FL back side 8 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
2.5. Device identification/name plate The name plate is located on the rear side of DLT-V6210FL. It must remain legible at all times for the purpose of identifying the device. Do not damage the name plate or remove it from the device.
3.3. Internal speaker, sound DLT-V6210FL is equipped with an internal speaker as standard (2 W). The system messages from the industrial PC are output via this speaker. The internal speaker can be configured in the audio settings of operating system in question.
WARNING / ADVERTISSEMENT Risk of injury due to weight and sharp-edged parts. DLT-V6210FL can fall down and cause injuries due to its weight. The strain relief rail can have sharp edges and cause cutting injuries. Always hold DLT-V6210FL by the housing with both hands.
Place devices front-to-front in this case. The VESA mounting point on the rear side of the device can damage the touchscreen of another device. Use protective material (non-flammable!) between the devices as precaution. Advantech Europe B.V. DLT-V6210FL Manual V1.21 13 / 69...
Configuration 5. Configuration Basic software settings for DLT-V6210FL are defined at the factory, for example with regard to Wi-Fi settings, network settings, etc. To adapt this, use the configuration tool for the respective DLT-V6210FL operating system: Win 10 IoT Ent.
Observe the applicable regulations for your deployment location/country with regard to channels, frequencies and the maximum permissible transmitting power. Responsibility for this lies with the company operating the DLT-V6210FL. The regulatory authorities in the relevant country can provide information on this.
Page 16
La responsabilité en incombe à l'entreprise qui exploite le DLT-V6210FL. Les autorités réglementaires du pays concerné peuvent fournir des informations complémentaires à ce sujet. Antenna solutions for use in Germany The Advantech antenna solutions are based on the prevailing IEEE 802.11 standard.
Do not use DLT-V6210FL near pacemakers. Always keep a distance of at least 20 to 50 cm between a pacemaker and DLT-V6210FL to reduce the risk of interference. Before using the device please obtain information about the use of the device within ...
Radio wave emission in the vicinity of persons. To ensure that the limits set for exposure to radio waves are not exceeded: Mount DLT-V6210FL so that persons maintain a minimum distance of 20 to 50 cm to the antenna.
Page 19
Mechanical mounting Pour vous assurer que les limites fixées pour l'exposition aux ondes radio ne sont pas dépassées: installez le DLT-V6210FL de sorte que les utilisateurs soient a une distance minimale de 20 cm de l'antenne. NOTICE: Physical damage Mounting environment without cooling air can overheat/damage DLT-V6210FL.
Risk of injury due to weight and sharp-edged parts. DLT-V6210FL can fall down and cause injuries due to its weight. The strain relief rail can have sharp edges and cause cutting injuries. Always hold DLT-V6210FL by the housing with both hands.
Requirement: The installation location / vehicle must be prepared (e.g. connection to the ignition, correct voltage, etc.) We recommend the following sequence: Determine a suitable mounting position for DLT-V6210FL. Secure device mounting at the vehicle/targeted object (RAM Mount etc.). Connect external accessories to DLT-V6210FL.
6.3.1. Use the VESA mounting hole pattern DLT-V6210FL has a 75 x 75 mm mounting hole pattern for fastening VESA compatible mountings to the rear side of the device. Fig. 6.1: Position VESA drill holes of DLT-V6210FL 22 / 69 DLT-V6210FL Manual V1.21...
NOTES: − Observe the maximum screw-in depth of the holes on the DLT-V6210FL. Screws that are too long can penetrate the back of the terminal and cause irreparable damage. In addition to the mounting bracket, one accessory holder per side can still be fastened in each −...
6 x Screw Cyl.int.hex DIN912 M6x16 A2 TufLok Fig. 6.3: Fasten mounting for frontal keyboard NOTE: Observe the maximum screw-in depth of the holes on the DLT-V6210FL. − Screws that are too long can penetrate the back of the terminal and cause irreparable damage.
Washer A6.4 DIN125 FE/ZN FORM A Nut M4 hex. with Cone Washer Angle holder right handheld scanner Spring clip Spring clip complete Connection plate 4 spring clip handheld scanner Cover cap protec. plastic RPC-2 A3.2 B14.7 Advantech Europe B.V. DLT-V6210FL Manual V1.21 25 / 69...
− Fig. 6.6: Fasten scanner holder NOTE: Observe the maximum screw-in depth of the holes on the DLT-V6210FL. − Screws that are too long can penetrate the back of the terminal and cause irreparable damage. Mounting sequence if mounting bracket and additional accessory are being fastened: First fasten the mounting bracket to the DLT-V6210FL.
2 x Washer ISO 8738 (DIN 1440)-A6-A2 Fig. 6.7: Fasten Mounting kit for touch stylus NOTES: Observe the maximum screw-in depth of the holes on the DLT-V6210FL. − Screws that are too long can penetrate the back of the terminal and cause irreparable damage.
DLT-V6210FL may only be connected to a SELV circuit (Safety Extra Low Voltage). The SELV circuit is a secondary circuit that is designed to protect the voltage from exceeding the safe value when operation runs correctly or a single error occurs.
DANGER Electrical shock due to insufficient EMERGENCY shut-off switch. If the EMERGENCY-OFF switch of the vehicle does not switch off DLT-V6210FL, there is a risk of electrical shock. Install DLT-V6210FL and the EMERGENCY-OFF switch so that DLT-V6210FL also ...
Page 30
CPU. All cable shields and the housing are connected to shield ground. The chassis of some forklifts is on DC+. This means that DLT-V6210FL chassis is also on DC+. Short circuits can arise when, for example, the ground potential of a peripheral device is on DC-.
Electrical installation, cable connection, cable cover 7.2. Preparations for installation Lay out all cables which are ready to be connected to DLT-V6210FL. Select the appropriate slot on the connector panel of DLT-V6210FL. Check and test which order of the cables routing is the best to fit in the cable compartment.
Plug the power supply cable into the power supply plug- in location. Tighten both mounting screws hand-tight. The screws required for this are already fixed in the delivered cable plug. 32 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Page 33
As a delivery standard, screws and cable clips are fixed on the DLT-V6210FL strain relief rail. Unscrew and remove the screws and the cable clip fixed on the cable passage you want to use for ...
Secure it to the strain relief rail using cable clip and appropriate screws: For thinner cables: Phillips screws M3x5L For regular cables: Phillips screws M3x10L For thicker cables: Hexagon screws M3x12L Fig. 7.2: Result (example): Cables connected in the cable compartment 34 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Page 35
Only use accessories that have been tested and approved by Advantech for the respective DLT-V6210FL. DLT-V6210FL may not be connected to the power supply if external devices are being connected/removed (not applicable for USB devices) Otherwise considerable damage could be caused to both DLT-V6210FL and the peripheral ...
Page 36
The device is not completely sealed due to incorrect attachment of the cables and the cable cover. The protection class/category of DLT-V6210FL is only ensured if the cable cover is properly installed. Improper installation can result in liquid penetrating into DLT-V6210FL during operation.
DLT-V6210FL is connected with three supply cables. DC+ and DC- are directly connected to the power supply, the connection is run through fuses. The supply voltage is then linked to DLT-V6210FL’s ignition input via a switch, for example, the key switch of the ignition (also with a fuse).
Page 38
“WM_QUERYENDSESSION”, i.e. the backup data must be saved without user confirmation and within the preset time. Configuration „MDevice program” is used to configure the automatic shutdown function. The „MDevice manual” can be found online in www.advantech.com/ 38 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Time between switching off and on: 10 seconds After DLT-V6210FL is shut down and switched off, it needs to wait at least 10 seconds until the device can react to a switch-on signal (<Power> button / ignition).
− Suitable touch stylus − Multi-touch capability Depending on the installed operating system type, the PCT touchscreen of DLT-V6210FL is multi-touch capable. This means it can detect two touch points simultaneously. 40 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Blinking : 0.2 sec. on / 0.8 sec. off Temperature sensor faulty Ambient temperature lies beyond the Blinking : 0.5 sec. on / 0.5 sec. off permitted range Advantech Europe B.V. DLT-V6210FL Manual V1.21 41 / 69...
Installed on flash When a DLT-V6210FL is started up for the first time without a pre-insallted operating system, the user needs to carry out a number of steps that will vary depending on the system to be installed. Refer to the relevant operating system manual for specific instructions.
Now you can see that MS-Windows Updates is adjusted to Never check for updates. Fig. 9.2: Win10 Automatic Updates To deactivate Never check for Updates: Manually delete the MS-Windows Registry entry. Reboot the System. Search updates once again to change the MS-Windows update state. Advantech Europe B.V. DLT-V6210FL Manual V1.21 43 / 69...
The SIM-Card needs to be placed in the SIM-Sockel under the cable cover WWAN settings & Test (Win10 IoT Enterprise) At DLT-V6210FL, WWAN Module’s driver already bundles into OS Image and NO need to do additional driver installation. Status of WWAN-Connection part of taskbar Fig.
DLT-V62 SW settings Fig. 9.4: WWAN Taskbar Status Connected Detailled WWAN information are available by opening the network settings Advantech Europe B.V. DLT-V6210FL Manual V1.21 45 / 69...
10.1. Connectors under the cable cover Fig. 10.1: Connectors under the cable cover (1x RSMA WIFI; 2x RP-SMA WWAN optional) Fig. 10.2: standard SIM-card extension including adapter under the cable cover 48 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Depending on the cable layout and interference from the environment, it may be impossible to use the cable length of 100 m given in the specification (IEEE 802.3 standard). The recommendation in this context is to use a shorter cable. Advantech Europe B.V. DLT-V6210FL Manual V1.21 49 / 69...
Only use CFast cards that have been approved by Advantech. NOTICE: Physical damage Improper opening of the antenna cap can impair the function of entire DLT-V6210FL system and in particular the Wi-Fi functionality. The antenna cap may only remain open during the service work.
Integrated power supply unit Integrated power supply unit DLT-V6210FL is equipped with a galvanically separated, integrated DC power supply unit. Power is connected to the back of the unit using a Phoenix Contact plug. There is no power switch. Power supply...
Fig. 11.1: DC power supply connector with power cable connector detail view Explanation: “Ignition on” means that a control signal can be routed to this connection that matches the supply voltage level. The signal reference is DC-. 52 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
4 (=Ground) Fig. 11.3: DC Power supply cable pin assignment Cable color Assignment Black / 黑 DC- 負 (negative) Red / 紅 DC+ 正 (positive) Brown / 棕 Green / 綠 Advantech Europe B.V. DLT-V6210FL Manual V1.21 53 / 69...
Wi-Fi IEEE 802.11 a/b/g/n Dual Band Diversity Number of antennas Type Omnidirectional antenna Directionality Optimized for the DLT-V6210FL housing Frequency range Band 1: 2400 to 2485 MHz Band 2: 5150 to 5875 MHz Antenna gain Max. 5 dBi (without loss through the cable) Impedance 50 Ω...
N type or TNC N, jack, female, bottom RSMA plug for RSMA socket on the terminal Scope of delivery 3 m antenna cable Maximum transmitting 100 mW / 20 dBm power Advantech Europe B.V. DLT-V6210FL Manual V1.21 55 / 69...
Integrated in the device at the factory by Advantech (internal PCIe MiniCard slot). Driver Generally, only drivers for Wi-Fi cards approved by Advantech can be integrated into operating system images. Maximum radiated power 100 mW EIRP 56 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Standard and Optional equipment 12.5. Keyboards and keyboard mounts (optional) A USB keyboard can be connected to DLT-V6210FL. Advantech offers the following keyboards and mountings: − SMALL keyboard − Mountable − Protection class IP65 Keyboard layouts: German, English, − French Fig.
Fig. 12.8: Touch stylus example 12.8. USB recovery stick (optional) The optional Advantech recovery stick allows images to be backed up and restored onto DLT-V6210FL when necessary (backup & recovery). Please contact your Advantech Europe B.V. sales representative if needed.
Check whether all connected cables are secured and the cable cover shuts tightly. WARNING Risk of accident due to unstable attachment of DLT-V6210FL. If the attachment of DLT-V6210FL becomes loose and breaks during moving, this can lead to severe accidents. Perform checks for the attachment as described above at regular intervals.
Do not use any abrasive glass cleaner or cloths that could scratch the touchscreen. Cleaning the housing Ensure that DLT-V6210FL is switched off and currentless. Clean the housing with a slightly dampened cloth. Do not use compressed air, a high-pressure cleaner or vacuum cleaner, as this can damage the ...
You can use Reset to reset the software recalibration. Please contact Advantech Europe B.V. if DLT-V6210FL malfunctions. You can find the contact address in section Technical customer support, page 67. Reasonably foreseeable misuse...
16.1. EMC guideline 16.1.1. Shielded components All components connected to the DLT-V6210FL, as well as cable connections must meet the legal EMC requirements for compliance with the EMC legislation. Screened bus, LAN cables and connectors must be used. 16.1.2. EMC EU DLT-V6210FL devices fulfill the requirements of the EU Directive "„2014/30/EU Elektromagnetische...
(2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Advantech Europe B.V. DLT-V6210FL Manual V1.21 63 / 69...
Page 64
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matérial brouilleur: “Appareils Numériques,” NMB-003 édictée par l’Industrie. FCC ID: M82-DLV6210FL IC: 9404A-DLV6210FL SW: V1.0 HW: V1.0 64 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
RED (Radio Equipment Directive) 2014/53/EU With regard to the RED (Radio Equipment Directive) 2014/53/EU the statements as below in the declaration of conformity for DLT-V6210FL industrial PC to apply. Česky Toto zařízení je v souladu se základními požadavky a ostatními [Czech]: odpovídajícími ustanoveními Směrnice 2014/53/EU.
In France, Wi-Fi operation outdoors is only permitted in the 2454 – 2483.5 MHz range at max. − 10 mW EIRP. 16.4. CE marking The devices of DLT-V6210FL series were tested and fulfill the CE conformity requirements and carry the CE mark on the rear side of the device. 16.5. Taiwan BSMI screen warning WARNING 使用過度恐傷害視力.
Comply with the provisions of the applicable EU directives, including their amendments applicable at the time of the declaration. For getting, the detailed declarations of conformity please visit our websites and contact your regional person in charge: www.advantech.com/ www.advantech.eu Advantech Europe B.V. DLT-V6210FL Manual V1.21 67 / 69...
[ ] Unit was already damaged on delivery (please enclose a copy of the delivery note) [ ] Delivery was incomplete Missing parts: [ ] The following error occurs when operating the unit: [ ] Separate error report is enclosed 68 / 69 DLT-V6210FL Manual V1.21 Advantech Europe B.V.
Need help?
Do you have a question about the DLT-V6210FL and is the answer not in the manual?
Questions and answers