Using the Console
Warning display
Display of regenerative load factor
With externally added resistor, this display is active when parameter Pr6C is set to "0" or "1".
Display of overload factor
See also "Overload Protection Time-limiting Characteristics" on Page 146.
Display of inertia ratio
Display of total number of feedback pulses and total number of control pulses
Total number of the pulses after
turning on the control power.
This display overflows as shown
on the right.
The indicated total pulse number can be reset (comes to 0) by pressing
•••Can not be used.
•••Can not be used.
Auto recognition of motor
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
No occurrence of warning
Warning of overload: Load has exceeded 85% of the level where overload
protection alarm occurs.
Warning of regenerative overload:
Regenerative load has exceeded 85% of the level where regenerative overload protection
alarm occurs. When externally added regenerative resistor, Parameter No. 6C, is selected
to be "1", the alarm is set to occur at 10% of the full working level of the regenerative resistor.
For manufacturer use : Can not be used.
Regenerative resistor load factor is indicated as a percentage with
reference to 100% level where regenerative protection is activated.
Load factor is indicated as a percentage with reference to the rated load 100%.
Inertia ratio is indicated in percent.
CW direction
Auto recognition is active (always indicated as shown on the left).
Occurrence of warning
0
Turning on the
−32768 pulses
control power −32768 pulses
S
SET
56
32767 pulses
CCW direction
about 5 seconds or more.