Parameter Setting
PrNo.
Parameter Name
70
1st over-speed
level set-up
2nd torque limit
71
set-up
2nd position over-
72
deviation set-up
2nd over-speed
73
level set-up
<Remarks>
For any use example of hit-and-stop initialization or press load pressing control using Pr70 to Pr73, see Pages 207 and 208 of
Reference edition.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Range of
Settings
0 - 6000
Pr.06=2 The parameter sets a 1st overspeed level when torque limit switching input is
[0]
enabled. If rotation speed of the motor exceeds this setting when the first torque limit is
selected, overspeed error will be generated. The unit is [r/min].
This parameter will be invalid when the torque limit switching input is disabled.
Pr.06=2 The parameter sets a 2nd torque limit when torque limit switching input is
0 - 500
enabled. This setting will be a limit value of the motor output torque when the second
[0]
torque limit is selected. Set this in terms of [%] to rated torque of the motor.
This parameter will be invalid when the torque limit switching input is disabled.
Pr.06=2 The parameter sets a 2nd excessive position deviation range when torque limit
1 - 32767
switching input is enabled. The unit is [256 x resolution].
[1875]
This parameter will be invalid when the torque limit switching input is disabled.
Pr.06=2 The parameter sets a 2nd overspeed level when torque limit switching input is
0 - 6000
enabled. If rotation speed of the motor exceeds this setting when the second torque limit
[0]
is selected, overspeed error will be generated. The unit is [r/min].
This parameter will be invalid when the torque limit switching input is disabled.