Chapter 1
Before you begin............................................................................................................ 7
1.1 About this manual............................................................................................................................ 7
1.2 Communications tools and protocols............................................................................................... 7
1.3 Related documents.......................................................................................................................... 7
Quick start..................................................................................................................... 9
2.1 Power up the transmitter..................................................................................................................9
2.2 Check meter status...........................................................................................................................9
2.3 Commissioning wizards..................................................................................................................10
2.4 Make a startup connection to the transmitter.................................................................................10
2.5 Set the transmitter clock................................................................................................................ 10
2.6 View the licensed features.............................................................................................................. 11
2.7 Set informational parameters......................................................................................................... 11
2.8 Characterize the meter (if required)................................................................................................12
2.9 Verify mass flow measurement.......................................................................................................15
2.10 Verify the zero.............................................................................................................................. 16
Chapter 3
Introduction to configuration and commissioning........................................................19
3.1 Security and write protection......................................................................................................... 19
3.2 Work with configuration files..........................................................................................................24
Chapter 4
Configure process measurement..................................................................................31
4.1 Configure Sensor Flow Direction Arrow ..........................................................................................31
4.2 Configure mass flow measurement................................................................................................ 32
4.3 Configure volume flow measurement for liquid applications.......................................................... 37
4.4 Configure Gas Standard Volume (GSV) flow measurement.............................................................41
4.5 Configure density measurement.................................................................................................... 46
4.6 Configure temperature measurement............................................................................................48
4.7 Configure Pressure Measurement Unit .......................................................................................... 50
4.8 Configure Velocity Measurement Unit ........................................................................................... 51
Chapter 5
Configure process measurement applications.............................................................. 53
5.1 Set up the API referral application .................................................................................................. 53
5.2 Set up concentration measurement............................................................................................... 65
5.3 Configure the batching application................................................................................................ 84
Chapter 6
Configure advanced options for process measurement................................................ 97
6.1 Configure Response Time .............................................................................................................. 97
6.2 Detect and report two-phase flow.................................................................................................. 97
6.3 Configure Flow Rate Switch ........................................................................................................... 99
6.4 Configure events.......................................................................................................................... 100
6.5 Configure totalizers and inventories............................................................................................. 102