STARTING IN THE FIELD

STARTING

Turn on the control (button on the side of the control box) and turn on the oil flow to
the machine. Fold up the chute and rotate this to the desired position.
Then move the machine to the operating position.
Reset and check the metal detector:
Lights on the control box:
Fig. 6-3
The green light indicates that the control system is on.
Fig. 6-4
The green light on the left-hand side indicates that the machine is operating with
normal feed intake and that the metal detector is activated.
The red light on the right-hand side indicates that the machine is in "metal stop", This
means that the electronic system has detected metal and the system has responded
(the pawl blocks the ratchet wheel and the reverse system switches to the neutral
position). A flashing light indicates that the power to the control system has been
turned off. This may be because the box has been turned off, but may also be due to
a loose connection.