4 Installation and Wiring
Precautions for Correct Use
• Use cables with suitable wire sizes for the carrying current. There are also restrictions on the
current due to the ambient temperature. Refer to the manuals for the cables and use the ca-
bles correctly for the operating environment.
• For twisted wires, strip the sheath and twist the conductor portion. Do not unravel or bend the
conductor portion of twisted wires or solid wires.
Additional Information
If more than 2 A will flow on the wires, use plated wires or use ferrules.
Connecting and Removing Wires
This section describes how to connect and remove wires.
 Terminal Block Parts and Names
 Required Tools
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
Side view
8° to 12°
0.4 mm
Recommended screwdriver
4 - 10
Unravel wires
Release hole
Terminal hole
Front view
2.5-mm dia.
2.5 mm
NX-series Analog I/O Units User's Manual for High-speed Analog Input Units (W592)
Bend wires