9 Troubleshooting
Event name
Unit Over Range for Channel 3
Meaning
The analog input data for input channel 3 exceeded the upper limit of the input range. Or, the analog
output data for output channel 3 exceeded the upper limit of the output range.
Source
Depends on where the Support
Software is connected and the
system configuration.
Error attrib-
Level
utes
Recovery
Effects
User program
System-de-
Variable
fined varia-
None
bles
Cause and
Assumed cause
correction
The analog input data exceeded
the upper limit of the input range.
Or, the analog output data ex-
ceeded the upper limit of the out-
put range.
Attached in-
None
formation
Precautions/
You can change the event level to the minor fault level.
Remarks
Event name
Unit Over Range for Channel 4
Meaning
The analog input data for input channel 4 exceeded the upper limit of the input range. Or, the analog
output data for output channel 4 exceeded the upper limit of the output range.
Source
Depends on where the Support
Software is connected and the
system configuration.
Error attrib-
Level
utes
Recovery
Effects
User program
System-de-
Variable
fined varia-
None
bles
Cause and
Assumed cause
correction
The analog input data exceeded
the upper limit of the input range.
Or, the analog output data ex-
ceeded the upper limit of the out-
put range.
Attached in-
None
formation
Precautions/
You can change the event level to the minor fault level.
Remarks
9 - 28
Source details NX Unit
Observation
Reset error in the NX Unit.
Continues.
Operation
Data type
---
Correction
Find the reason for exceeding
the upper limit of the input or out-
put range and make suitable cor-
rections.
Source details NX Unit
Observation
Reset error in the NX Unit.
Continues.
Operation
Data type
---
Correction
Find the reason for exceeding
the upper limit of the input or out-
put range and make suitable cor-
rections.
NX-series Analog I/O Units User's Manual for High-speed Analog Input Units (W592)
Event code
64F20000 hex
Detection tim-
ing
Log category
System
If the input range is exceeded, the converted value
will be the upper limit of the input range. If the out-
put range is exceeded, the analog output will be
the upper limit of the output range.
Name
---
Prevention
Find the reasons for exceeding
the upper limit of the input or out-
put range and take suitable pre-
ventive measures.
Event code
64F30000 hex
Detection tim-
ing
Log category
System
If the input range is exceeded, the converted value
will be the upper limit of the input range. If the out-
put range is exceeded, the analog output will be
the upper limit of the output range.
Name
---
Prevention
Find the reasons for exceeding
the upper limit of the input or out-
put range and take suitable pre-
ventive measures.
Continuously
Continuously