2-1-1

General Specifications

This section provides the general specifications of the High-speed Analog Input Units.
Enclosure
Grounding methods
Operating en-
vironment
Applicable standards
Note 1. The specifications of insulation resistance and dielectric strength vary with NX Unit Models.
Note 2. Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most re-
cent applicable standards for each model.
2-1-2

Individual Specifications

Refer to A-1 Data Sheet on page A - 2 for the individual specifications of the High-speed Analog
Input Units.
2 - 2
Item
Ambient operating temper-
ature
Ambient operating humidi-
ty
Atmosphere
Ambient storage tempera-
ture
Altitude
Pollution degree
Noise immunity
Overvoltage category
EMC immunity level
Vibration resistance
Shock resistance
Insulation resistance
Dielectric strength
NX-series Analog I/O Units User's Manual for High-speed Analog Input Units (W592)
Specification
Mounted in a panel
Ground of 100 Ω or less
0 to 55°C
10% to 95% (with no condensation or icing)
Must be free from corrosive gases.
-25 to 70°C (with no condensation or icing)
2,000 m max.
2 or less: Conforms to JIS B 3502 and IEC 61131-2.
Conforms to IEC 61000-4-4, 2 kV (power supply line)
Category II: Conforms to JIS B 3502 and IEC 61131-2.
Zone B
Conforms to IEC 60068-2-6.
5 to 8.4 Hz with amplitude of 3.5 mm,
8.4 to 150 Hz, acceleration of 9.8 m/s
100 min each in X, Y, and Z directions (10 sweeps of 10 min
each = 100 min total)
Conforms to IEC 60068-2-27, 147 m/s
and Z directions
Refer to the individual specifications of NX Units.
Refer to the individual specifications of NX Units.
cULus: Listed (UL61010-2-201), ANSI/ISA 12.12.01, EU: EN
61131-2, RCM, KC (KC Registration), and EAC
2
2
, 3 times each in X, Y,