Omron Sysmac NX Series User Manual page 135

Machine automation controller analog i/o units high-speed analog input units
Hide thumbs Also See for Sysmac NX Series:
Table of Contents

Advertisement

Letter
(c)
Task period of assigned periodic
tasks
(d)
Unit operation
settings
(e)
Update I/O Entry Button
(f)
Apply Button
(g)
Cancel Button
(h)
OK Button
(i)
Status of whether I/O entry that
matches the set values of Unit
operation settings has been set
*1.
Refer to 8-4 Number of Samplings Setting on page 8 - 8 for the calculation formula for the sampling peri-
od.
NX-series Analog I/O Units User's Manual for High-speed Analog Input Units (W592)
Name/Label
The task period of assigned periodic task in the task settings is dis-
played.
In the Unit operation settings, the settings and set values that affect
the I/O allocations are displayed. The sampling period and frequen-
cy values are also displayed.
Ch
The analog input channel numbers are displayed.
Enable/Disable
Values that you set for Ch£ Enable/Disable in the Unit operation
setting
settings are displayed.
Number of
Values that you set for Ch£ Number of Sampling Settings in the
samplings set-
Unit operation settings are displayed.
ting
For disabled channels, - is displayed in the Ch column.
Sampling peri-
The sampling period for each channel, which is automatically calcu-
od [µs]
lated by the Support Software, is displayed.
For disabled channels, - is displayed in the Ch column. In addition,
for channels whose sampling period is less than 5 µs, the Ch num-
ber is displayed in red text.
Sampling fre-
The sampling frequency for each channel, which is automatically
quency [kHz]
calculated by the Support Software, is displayed.
For disabled channels, - is displayed in the Ch column.
Click this button to update the I/O entry to match the set values of
the Unit operation settings.
You can click the Update I/O Entry Button only when no I/O entry
that matches the set values of the Unit operation settings has been
set.
Click this button to enable the settings in the Edit I/O Allocation Set-
tings Window.
Click this button to return to the CPU and Expansion Racks Tab
Page or Edit Slave Terminal Configuration Tab Page.
If you click this button after clicking Update I/O Entry Button, the
following dialog box is displayed to confirm whether to cancel the
I/O allocation settings.
Click the OK Button in this dialog box to cancel the settings in the
Edit I/O Allocation Settings Window, and return to the CPU and Ex-
pansion Racks Tab Page or Edit Slave Terminal Configuration Tab
Page. Or click the Cancel Button to return to the Edit I/O Allocation
Settings Window.
Click this button to enable the settings in the Edit I/O Allocation Set-
tings Window, and return to the CPU and Expansion Racks Tab
Page or Edit Slave Terminal Configuration Tab Page.
This shows the status of whether an I/O entry that matches the set
values of Unit operation settings has been set. If no I/O entry that
matches the set values of the Unit operation settings has been set,
click the Update I/O Entry Button.
7 I/O Data and List of Settings
Description
*1
*2
7
7 - 17