B.7 ADAM-5013 RTD Input Format and Ranges

Range
Code (hex)
20
21
22
23
24
25
26
Note:
See next page for table continuation.
ADAM-5000/TCP User's Manual
Data Formats and I/O Ranges
Input Range
Description
100 Ohms Platinum
RTD -100 to 100° C
a=0.00385
100 Ohms Platinum
RTD 0 to 100° C
a=0.00385
100 Ohms Platinum
RTD 0 to 200° C
a=0.00385
100 Ohms Platinum
RTD 0 to 600° C
a=0.00385
100 Ohms Platinum
RTD -100 to 100° C
a=0.00392
100 Ohms Platinum
RTD 0 to 100° C
a=0.00392
100 Ohms Platinum
RTD 0 to 200° C
a=0.00392
Maximum
Specified
Data Formats
Signal
Engineering
+100.00
Units
Engineering
+100.00
Units
Engineering
+200.00
Units
Engineering
+600.00
Units
Engineering
+100.00
Units
Engineering
+100.00
Units
Engineering
+200.00
Units
Appendix B
Minimum
Displayed
Specified
Resolution
Signal
-100.00
±0.1° C
+000.00
±0.1° C
+000.00
±0.2° C
+000.00
±0.6° C
-100.00
±0.1° C
+000.00
±0.1° C
+000.00
±0.2° C
B-10