Example: To define the Serial Trigger Character as a lowercase c, enter
<Kic>.
External Trigger Level
Format: <Kjexternal trigger level>
external trigger level (initiates a read cycle):
0 = Negative
1 = Positive
Example: To change External Trigger Level to Negative, enter <Kj0>.
Noread Message
Format: <Kkstatus,message>
status:
message:
0 = Disabled
Any ASCII string up to 7 digits. Default is NOREAD.
1 = Enabled
Example: To enable Noread Message and send the message "FAIL," enter
<Kk1,FAIL>.
Bar Code Output
Format: <Klstatus,when to output>
status:
when to output:
0 = Disabled
0 = As Soon As Possible
1 = Enabled
1 = End of Read Cycle
Example: To set When to Output to End of Read Cycle, enter <Kl3,1>.
Good Decode Reads
Format: <Kmnumber of reads>
number of reads (before a good decode):
Any number from 1 to 31.
Default is 1.
Example: To change Good Decode Reads to 3, enter <Km3>.
Match Code
Format: <Knstatus>
status:
0 = Disabled
1 = Enabled
Example: To enable Match Code, enter <Kn1>.
MS-610 Scanner User's Manual
Operations Commands
3-9