Chapter 3
Serial Configuration
Code Types Commands
Narrow Margins
Format: <Kostatus>
status:
0 = Disabled
1 = Enabled
Example: To enable Narrow Margins, enter <Ko1>.
Code 39
Format: <Kpstatus,check digit status,check digit
output status,large intercharacter gap,fixed code
length status,code length>
status:
0 = Disabled
1 = Enabled
large intercharacter gap:
0 = Disabled
1 = Enabled
Example: To set Fixed Code Length to 30, enter <Kp,,,,1,30> or
<Kp1,0,0,0,1,30>.
Codabar
Format: <Kqstatus,start & stop match status,start & stop output
status,large intercharacter gap,fixed code length status,code length>
status:
0 = Disabled
1 = Enabled
large inter-character gap:
0 = Disabled
1 = Enabled
Example: To set Fixed Code Length to 9, enter <Kq,,,,1,9> or
<Kq1,1,1,0,1,9>.
3-10
MS-610 Scanner User's Manual
check digit status:
check digit output
status:
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
fixed code length status:
code length:
0 = Disabled
Any number from 1 to
1 = Enabled
31. Default is 10.
start & stop match status:
start & stop output
status:
0 = Disabled
1 = Enabled
0 = Disabled
1 = Enabled
fixed code length status:
code length:
0 = Disabled
Any number from 1
1 = Enabled
to 31. Default is 10.
Need help?