Figure 2-6 Match Code Logic Diagram - Microscan MS-615 User Manual

Table of Contents

Advertisement

Chapter 2
Menu Configuration
Figure 2-6 on page 2-18 shows the sequence of operation (and reference)
for setting up and entering master labels.
Enable Match Code:
1. by menu selection
(page 2-17),
2. by operational
command <E>, or
3. by serial configuration
command <Kn1>
If Match Code is enabled, Relay Driver (page 2-28) must be set to an option
other than Good Read. If Relay Driver is set to Good Read, there will be no
output to the host or a relay pulse.
2-18
MS-610 Scanner User's Manual
* See the option/outputs available in the relay
driver you have selected (page 2-26).
Enable New Master Pin:
1. by menu selection, or
2. by serial configuration
command <Kz1>
Enter the next label scanned
as the master label:
1. by operational command <G>
Download a new master
label directly into memory:
1. by operational command
<)XXXX)>

Figure 2-6 Match Code Logic Diagram

Toggle internal pin 5 to
GND (pin 12) to enter
next label scanned
as the master label.
Read in the
master label.
Compare the
master label with sub-
sequent labels*