9
Install Scanner
The MS-610 scanner can be mounted directly to a mounting surface of your
choice, or indirectly, via a mounting plate.
To permanently mount the scanner:
1. Position the scanner in a dry place, devoid of sunlight, bright lights, or
laser light from other sources.
b. Before mounting, ensure sufficient clearance at the rear of the scanner
to allow for the 15-pin connector and cable.
c. If not using the mounting plate, use the measurements provided in
figure 1-9 to locate centers of mounting holes and drill four 5/32 inch (4
mm) holes, or
If using the mounting plate (see appendix D), use the four
perimeter holes to mount the plate and mount scanner directly to
the four inner holes on the plate.
d. Secure scanner with four 6-32 screws.
2.25" (57.15 m m)
1.40" (35.56 m m)
2.29 "
(74.17 mm )
Front
Figure 1-9 Bottom Mounting Holes (not full size)
MS-610 Scanner User's Manual
Install Scanner
Caution: Do not allow
the mounting screws
.425 "
(10.8 mm )
to penetrate into the
scanner case more
than 0.175 in. (4.4
mm) or damage to the
1.0 "
(25.4 mm )
scanner may result.
Caution: To prevent
twisting or distortion of
the scanner housing,
ensure that the mount-
ing surface or bracket
1.50 "
is flat.
(38.10 mm )
6-32 threa ds
(4 places)
1-13
Need help?
Do you have a question about the MS-615 and is the answer not in the manual?