Microscan MS-615 User Manual page 41

Table of Contents

Advertisement

Good Decode Reads
Default:
1
Options: 1 to 31
Allows you to select the number of good reads (from 1 to 31) required per label
before a good decode output.
Note: Be sure to set the value within the determined scan rate for the scanning
setup so that the scanner is capable of scanning a label the required number of
times.
Match Code
Default:
Disabled
Options: Disabled, Enabled
Note: A triggered mode (page 2-11 to page 2-12) must be enabled for Match
Code to take effect.
Note: If both Match Code and Continuous Read are enabled the scanner
defaults to Continuous Read 1 Output mode, and the label data must change
before the scanner will output data again, unless a timeout, if enabled, occurs.
Allows you to enter a master label into the scanner's memory to be com-
pared with subsequently scanned labels.
With Match Code enabled, a master label can be entered in three ways:
1. With New Master Pin enabled (see page 2-27), toggling pin 5 to
ground (pin 12) enables the next good read to be the master label.
2. Sending serial command <G> enables the next good read to be the
master label.
3. Sending serial command <)XXXX)> downloads data as master label.
MS-610 Scanner User's Manual