Memory Allocated To Fcs; Processing Times Of Fcs - Siemens SIMATIC S7-300 Manual

Fm 354 servo drive positioning module
Hide thumbs Also See for SIMATIC S7-300:
Table of Contents

Advertisement

6.8
Technical specifications
Memory allocation
The following table gives you an overview of the memory allocated to FCs.
Table 6-9
1
2
3
4
5
6
Processing times
The following average processing times for FCs were measured with a CPU
314. The specified times are rounded:
Table 6-10
INIT_DB
MODE_WR
RD_COM
DIAG_RD
MSRMENT
DIAG_INF
Note
In distributed configurations (under development) it is possible to increase
the number of cycles.
FM 354 Servo Drive Positioning Module

Memory allocated to FCs

No.
FC
INIT_DB
224
MODE_WR
1226
RD_COM
774
DIAG_RD
302
MSRMENT
288
DIAG_INF
282

Processing times of FCs

FC
Transfer
Write control/checkback sig-
nals without data (job = 0)
Write control/checkback sig-
nals with data (job > 1)
Read data
Read process and diagnostic
interrupt data
Programming the FM 354
Block in bytes
MC7 code in
bytes
120
970
584
180
172
166
Cycle 1
1.3 ms
1.3 ms
3.0 ms
3.0 ms
Local data in
bytes
4
26
24
34
26
26
Cycle 2
Cycle 3
3.0 ms
1.3 ms
6-45

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents