Siemens SIMATIC S7-300 Manual page 132

Fm 354 servo drive positioning module
Hide thumbs Also See for SIMATIC S7-300:
Table of Contents

Advertisement

Starting up the FM 354
Table 7-3
Initial contents of machine data, continued
MD (E)
Value
1)
43
U
= 1,000...10,000 (mV)
max
44
0
45
0
1) This pair of values corresponds to the speed category of the drive. It serves as a basis for calculating the K
the servo, and must therefore be entered correctly.
Recommendation: So far as possible, U
7.3
Testing and optimization
Testing and
Once you have installed, wired and parameterized the unit, you can test and
optimization
optimize your FM 354 positioning module. Testing and optimization can be
information
performed with the aid of the testing and start–up interface with or without
the user program.
You can also test individual modes and their traversing programs, and view
and debug them during execution.
There are two ways of operating the FM:
This interface is installed with "Parameterize FM 354". Once the FM 354 has
been parameterized, you can call it up by selecting the menu Test Startup
or by selecting from the overview display.
7-6
Specified maximum amount of drive setpoint
Offset value for drive setpoint
Voltage ramp inactive
should be set in the range between 8 and 9 V.
max
CPU is in "STOP", test without user program
CPU is in "RUN", test with user program
You can monitor the interface between the FM and the user program. You
can also control the program from the start–up user interface when control
signal [TFB] (TEST_EN) is enabled in the user program. Example ap-
plication 3 (see Section 6.7) can be included in the user program for this
purpose.
Explanation
FM 354 Servo Drive Positioning Module