Text Id's El922X - Beckhoff EL922 Series Documentation

Electronic overcurrent protection terminals
Table of Contents

Advertisement

8.2

Text ID's EL922x

TextId
Type (en)
Place (En) MessageText (En)
Hex
0x1600 Information I/O General Cooling down time still
0x4611 Warning
I/O General Exceeding the maximum
0x4612 Warning
I/O General Undervoltage detected,
0x4613 Warning
I/O General Parameter-value is not
0x4614 Warning
I/O General Parameter-value not
0x470E Warning
0x817F Error
General
0x8620 Error
I/O General Undervoltage detected,
0x8621 Error
I/O General Overvoltage detected,
0x8622 Error
I/O General Reverse current detected,
0x8623 Error
I/O General Short circuit detected,
0x8624 Error
I/O General Overload detected, channel
EL922x
active, channel %d
sum of current (max. %d A)
channel %d
supported by this variant of
terminal, channel %d
allowed and was reduced
automatically, channel %d
Overtemperature in device
internal hardware error
(error code)
channel %d tripped
channel %d tripped
channel %d tripped
channel %d tripped
%d tripped
Version: 1.0
Add. comment
error code:
11 = missing input voltage channel 1
12 = missing input voltage channel 2
21 = faulty redundant current measurement
channel 1
22 = faulty redundant current measurement
channel 2
31 = overtemperature channel 1
32 = overtemperature channel 2
41 = measurement error channel 1
42 = measurement error channel 2
51 = wiring error, cable break Channel 1 or
input
52 = wiring error, cable break Channel 2 or
input
Diagnostics