Beckhoff EL922 Series Documentation page 128

Electronic overcurrent protection terminals
Table of Contents

Advertisement

Commissioning
Index 1C33 SM input parameter
Index (hex) Name
1C33:0
SM input parameter
1C33:01
Sync mode
1C33:02
Cycle time
1C33:03
Shift time
1C33:04
Sync modes sup-
ported
1C33:05
Minimum cycle time
1C33:06
Calc and copy time
1C33:07
Minimum delay time
1C33:08
Command
1C33:09
Maximum delay time
1C33:0B
SM event missed
counter
1C33:0C
Cycle exceeded
counter
1C33:0D
Shift too short counter Number of occasions that the interval between
1C33:20
Sync error
128
Meaning
Synchronization parameters for the inputs
Current synchronization mode:
• 0: Free Run
• 1: Synchron with SM 3 Event (no outputs
available)
• 2: DC - Synchron with SYNC0 Event
• 3: DC - Synchron with SYNC1 Event
• 34: Synchron with SM 2 event (outputs
available)
Cycle time (in ns):
• Free Run: Cycle time of the local timer
• Synchron with SM 2 Event: Master cycle time
• DC mode: SYNC0/SYNC1 Cycle Time
Time between SYNC0 event and reading of the in-
puts (in ns, only DC mode)
Supported synchronization modes:
• Bit 0: free run is supported
• Bit 1: Synchron with SM 2 Event is supported
(outputs available)
• Bit 1: Synchron with SM 3 Event is supported
(no outputs available)
• Bit 2-3 = 01: DC mode is supported
• Bit 4-5 = 01: Input shift through local event
(outputs available)
• Bit 4-5 = 10: Input shift with SYNC1 event (no
outputs available)
• Bit 14 = 1: dynamic times (measurement
through writing of 0x1C33:08)
Minimum cycle time (in ns)
Time between reading of the inputs and availability of
the inputs for the master (in ns, only DC mode)
• 0: Measurement of the local cycle time is
stopped
• 1: Measurement of the local cycle time is
started
The entries 0x1C33:03, 0x1C33:06, 0x1C33:09 are
updated with the maximum measured values.
For a subsequent measurement the measured val-
ues are reset.
Time between SYNC1 event and reading of the in-
puts (in ns, only DC mode)
Number of missed SM events in OPERATIONAL (DC
mode only)
Number of occasions the cycle time was exceeded in
OPERATIONAL (cycle was not completed in time or
the next cycle began too early)
SYNC0 and SYNC1 event was too short (DC mode
only)
The synchronization was not correct in the last cycle
(outputs were output too late; DC mode only)
Version: 1.0
Data type
Flags
Default
UINT8
RO
0x20 (32
UINT16
RW
0x0000 (0
UINT32
RW
0x000F4240
(1000000
UINT32
RO
0x00000384
(900
dec
UINT16
RO
0x8001 (32769
UINT32
RO
0x00002710
(10000
UINT32
RO
0x00000000 (0
UINT32
RO
0x00000384
(900
dec
UINT16
RW
0x0000 (0
UINT32
RO
0x00000384
(900
dec
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
UINT16
RO
0x0000 (0
BOOLEAN
RO
0x00 (0
)
dec
)
dec
)
dec
)
)
dec
)
dec
)
dec
)
)
dec
)
)
dec
)
dec
)
dec
)
dec
EL922x