*BUS +/- SIGNALS OPEN FROM SENTRY KEY IMMOBILIZER MODULE
Continued
TEST
5
Note: Ensure there is PCI Bus communication with other modules on the
vehicle before proceeding. If not, refer to the symptom list from the menu
and repair as necessary.
Disconnect the SKIM harness connector.
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
Select DRB Standalone.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Set Probe to x10.
Press F2 again when complete.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the SKIM connector.
Turn the ignition on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?
Yes → Replace the Sentry Key Immobilizer Module (SKIM) in accor-
→ Go To 6
No
6
Turn the ignition off.
Disconnect the SKIM harness connector.
Disconnect the BCM C1 harness connector.
Measure the resistance of the PCI bus circuit between the SKIM connector and the
BCM C1 connector.
Is the resistance below 5.0 ohms?
Yes → Replace the Body Control Module in accordance with the service
→ Repair the PCI Bus circuit for an open.
No
ACTION
dance with the service information.
information.
19
COMMUNICATION
APPLICABILITY
All
All