DRIVEABILITY - NGC
Symptom:
P0562-BATTERY VOLTAGE LOW
When Monitored and Set Condition:
P0562-BATTERY VOLTAGE LOW
When Monitored: Engine Running. RPM greater than 1152.
Set Condition: The battery sensed voltage is 1 volt below the charging goal for 13.47
seconds. The PCM senses the battery voltage turns off the field driver and senses the
battery voltage again. If the voltages are the same, the code is set. One trip Fault.
INTERMITTENT CONDITION
B+ CIRCUIT HIGH RESISTANCE
GENERATOR GROUND HIGH RESISTANCE
GENERATOR OPERATION
GENERATOR FIELD GROUND CIRCUIT OPEN
GENERATOR FIELD CONTROL CIRCUIT SHORTED TO GROUND
GENERATOR FIELD CONTROL CIRCUIT OPEN
PCM
TEST
1
NOTE: Ensure the Battery is in good condition. Using the Midtronics
Battery Tester, test the Battery before continuing.
NOTE: Inspect the vehicle for aftermarket accessories that may exceed the
Generator System output.
Turn the ignition off.
NOTE: Ensure the generator drive belt is in good operating condition.
NOTE: Inspect the fuses in the PDC. If a fuse is found to be open use the
wiring diagram/schematic as a guide, inspect the wiring and connectors for
damage.
Ignition on, engine not running.
With the DRBIII , read DTCs and record the related Freeze Frame data.
Is the Good Trip Counter displayed and equal to zero?
Yes → Go To 2
No
POSSIBLE CAUSES
ACTION
→ Go To 9
224
APPLICABILITY
All