B0069991 / Rev. 1.7

6 Communication with the PLC

The I20 has 10 galvanically isolated (opto coupled) inputs and 5 galvanically isolated (opto
coupled) outputs.
6.1

PLC inputs

If different functions are performed at the same time, an fault message will be generated.
The following functions are possible:
1. Measurement Start / Stop
2. System test (gap control sensors)
3. Program switching
4. Clear 2-sheet / Clear 0-1-2-wa outputs
5. Zero adjust (not active by default)
6. Material detection NF (with first selected sensor)
7. Teach-In 1-sheet (not active by default)
8. Teach-In 2-sheet (not active by default)
9. Reset Fault
6.2

PLC output signals

The following signals are available as outputs:
Signal
OUT3
OUT2
OUT1
OUT0
OUT4
6.2.1
Signal „Enable"
The signal ENABLE is always 24V active
The signal is LOW (0V)
during system operation via keyboard
in case of system fault
during a system test
The signal is HIGH (24V)
when the system is operational
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
Meaning
Note
0-sheet output
Standard 0 V active (selectable in system configuration)
1-sheet output
Standard 0 V active (selectable in system configuration)
2-sheet output
Standard 0 V active (selectable in system configuration)
ENABLE output
Standard 24 V active (not selectable, for safety reasons)
Warning
Standard 0 V active (selectable in system configuration)
If the external outputs or inputs are used, then the supply voltage for
Attention
the outputs / inputs needs to be connected.
Manual
Opto coupler outputs
Communication with the PLC
55