Roland Double Sheet Detector R1000 Series Manual page 88

Inductive principles – microcontroller based
Table of Contents

Advertisement

Start-up
Adjustment parameter 2: Selection of sensor test.
Adjust Parameter:
test Sensor distance
Fig. 70: Selection of sensor test
Possible choices:
• no: No sensor test will be performed.
• yes:
Adjustment parameter 3: Indication of the deviation of the sensor distances found.
Adjust Parameter:
deviation distance
Fig. 71: Sensor distances
By pressing the ENTER key the deviation of the investigated sensor distances are indicated (when
in „change" mode).
Adjust Parameter:
OK range:-200...+200
A1:
79
A3:
80
Fig. 72: Indication of deviation of sensor distances
Adjustment parameter 4: Calculation of the sensor distances.
Adjust Parameter:
distance sensors
Fig. 73: Scheduled parameter
By pressing the ENTER key the distance is calculated (in mm / inch).
Adjustment parameter 5: Control of sensors.
Adjust Parameter:
control sensors
Fig. 74: Control of sensors
Possible choices:
• no: The sensor allocation will not be tested.
• yes:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
88
Double Sheet Detector-series I20
2
no
The operator will be requested to remove all sheets. Then the system performs the
sensor test. If the test was done error-free, "Sensor distance OK" is displayed. If the
test shows faulty results, "Sensor distance too small" or "Sensor distance too large"
will be shown. Then the sensor distance should be checked / corrected.
3
3
A2:
82
A4:
85
4
5
no
The sensors are checked for correct wiring / allocation.
In case of fault-free test result „Sensor control OK" will be shown.
Manual
B0069991 / Rev. 1.7