Technical Data; Technical Data Control Unit I20 - Roland Double Sheet Detector R1000 Series Manual

Inductive principles – microcontroller based
Table of Contents

Advertisement

B0069991 / Rev. 1.7

2 Technical data

2.1

Technical data control unit I20

Technical data control unit I20
Operating voltage:
Power consumption:
Switch on current:
External fuse:
Ambient temperature:
Wall mount enclosure
Protection category:
Dimensions, approx.. (W x H x D) mm
Dimensions, approx.. (W x H x D) inch
Weight, approx
Front panel enclosure
Protection category:
Dimensions, approx.. (W x H x D) mm
Dimensions, approx.. (W x H x D) inch
Weight, approx
Additional characteristics:
255 parameter sets memory
Programming via front panel keys
10 galvanically isolated
optocoupler inputs 24 VDC with
common external supply
5 potential free outputs
with positive external supply
Virtual RS232 interface (via USB) for data backup
USB interface for Firmware update
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
Specification:
- min. switching voltage HIGH:
- max. switching voltage HIGH:
- min. switching voltage LOW:
- max. switching voltage LOW:
Specification:
- switching output:
- max. switching voltage:
- max. switching current:
In order to protect the outputs from damage by inductive spikes, the
Attention
outputs need to be protected by amply dimensioned flyback diodes.
Manual
24 VDC, +6 V / -4 V
15 W
10 A for 1 ms
1 A medium time lag
0 - 50 °C (30 - 122° F)
I20-2-O-S
IP65
225 x 206 x 112
8.9 x 8.1 x 4.4
4.0 kg (8.81 lbs)
Valid from SN-No. 104358 delivery date 09/03/2009
I20-2-O-S-FP
IP40 (inside), IP65 (front cover)
240 x 240 x 120
9.45 x 9.45 x 4.7
2.2 kg (4.85 lbs)
13 VDC
30 VDC
0 VDC
8 VDC
unwired Emitter and Collector
30 VDC
500 mA
Technical data
I20-4-O-S
225 x 206 x 112
8.9 x 8.1 x 4.4
I20-4-O-S-FP
240 x 240 x 170
9.45 x 9.45 x 6.7
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents