Roland Double Sheet Detector R1000 Series Manual page 85

Inductive principles – microcontroller based
Table of Contents

Advertisement

B0069991 / Rev. 1.7
If no Teach-In is present or if a Teach-In for Part A is to be repeated, select "statical" / "dynamical".
• Static:
• Dynamic:
Static Teach-In Part A:
Program Parameter: 8
search max/min:XXXXX
feed part A
then press ENTER
Fig. 60: Teach-In procedure for Part A
Place part A into the sensor gap. With the value shown in the display the position with the largest
value (positive) or respectively with the smallest value (negative) can be determined (depending on
the application). The Teach-In for part A is completed by pushing the Enter Key.
Dynamic Teach-In Part A:
Program Parameter: 8
Teach-In part A
drive part A through
then press ENTER
Fig. 61: Teach-In procedure for Part A
The Part A must be moved through the sensor gap in mid position. With the ENTER key the
measurement value will be stored.
After the
Teach-In for Part A
Program Parameter: 8
Teach-In part A
finished
push ENTER
Fig. 62: Teach-In finished
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
In order to use a parameter set for measurement, a Teach-In for
Note
Part A must have been performed.
The system will perform a punctual Teach-In for Part A.
Part A is moved through the sensor gap during Teach-In.
The position of the Part A for Teach-In must match with the
Note
position in measurement operation. Otherwise the measurement
result can become faulty.
the following message is shown:
Manual
Start-up
85