Operation; Abbreviated Operating Instructions - Roland Double Sheet Detector R1000 Series Manual

Inductive principles – microcontroller based
Table of Contents

Advertisement

B0069991 / Rev. 1.7

8 Operation

8.1

Abbreviated operating instructions

After applying power to the system and the version number are briefly displayed. Afterwards the
system switches into that measurement menu which was active before the unit was switched off.
Fig. 100: Frontal view of the I20 with enlarged display detail
LED functions (symbols above the keys)
ON, if the measured value reaches (or falls short of) the lower limit value.
<
ON, if the measured value is within the lower and upper limit values.
Norm
ON, if the measured value reaches (or exceeds) the upper limit value.
>
- blinks, if a fault is present
Enable
- ON, if the equipment is in measurement mode
- OFF, during parameter programming with the keyboard
Key functions (symbols below the keys)
Changes the parameters (forward)
Changes the parameters (backwards)
Selects a parameter for changing and confirming the change
Enter
Activates the menu level, for deleting a fault message and exiting the menu level.
Menu
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
The system is factory adjusted for "external continuous measurement".
Note
Therefore the system functions only if the signal "measurement start" is
activated via the PLC input. The modification of the configuration is
described in the following sections.
Manual
Operation
99