Roland Double Sheet Detector R1000 Series Manual page 11

Inductive principles – microcontroller based
Table of Contents

Advertisement

B0069991 / Rev. 1.7
2.3.2
Sensor pair IS42-30GS / IE42-30GS*
Technical data
Application:
Sheet thickness:
Sensor distance:
Measurement principle: Eddy current
Protection class:
Weight:
Material of enclosure:
Sensor cable:
* Transmitter ISQ42. and receiver IE42-30.. may be also used as a sensor pair. Please refer to
chapter 4.3.1 for an example.
2.3.3
Sensor pair ISQ42S / IEQ42S*
Sensor pair ISQ42FS / IEQ42FS*
Technical data
Application:
Sheet thickness:
Sensor distance:
Measurement principle: Eddy current
Protection class:
Weight:
Material of enclosure:
Sensor cable:
* Transmitter ISQ42S and receiver IE42-30S, respectively transmitter IS42-30S and receiver
IEQ42S may be also used as a sensor pair. Please refer to chapter 4.3.1 for an example.
2.3.4
Sensor pair ISQ160S / IEQ160S
Technical data
Application:
Sheet thickness:
Sensor distance:
Measurement principle: Eddy current
Protection class:
Weight:
Material of enclosure:
Sensor cable:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
Double sheet detection
0.15 – 8 mm
for steel
0.1 – 10 mm
for Aluminum (LW 20 – 30 MS/m):
0.4 – 10 mm
for austenitic Stainless steel
see sensor diagrams
IP54
ca. 0.45 kg (1 lbs)
Stainless steel / Brass, Nickel plated
Quick disconnect
Double sheet detection
0.15 – 8 mm
for steel
0.1 – 10 mm
for Aluminum (LW 20 – 30 MS/m):
0.4 – 10 mm
for austenitic Stainless steel
see sensor diagrams
IP54
ca. 0.50 kg (1.1 lbs)
Plastic
ISQ / IEQ42S:
Quick disconnect
ISQ / IEQ42FS:
0,2 m, cable firmly connected, with cable plug
Part inspection, Material inspection, Hardness inspection
Depending on the application
20 – 80 mm (depending on the application)
IP54
ca. 0.50 kg (1.1 lbs)
Plastic
Quick disconnect
The stated measurement ranges are only valid for systems in „Standard"
Note
setting. For details refer to chapter 3.2.
Manual
at nom. sensor distance (min. / max.)
40 (20 – 80) mm
40 (20 – 80) mm
40 (20 – 80) mm
at nom. sensor distance (min. / max.)
40 (20 – 80) mm
40 (20 – 80) mm
40 (20 – 80) mm
Technical data